Dear Amy

 

not sure If I understood your explanation. I try the other way around:

 

1.) You can use CBRC20 only for one regulation in one run. Therefore you can display only the results of either TSCA or TSCA 5A tracking

2.) If you select in CBRC20 TSCA then the TSCA results should show up and the TSCA Limits

 

Regarding;: So a TSCA PU is showing up in the T5A report with the TSCA limits.

this can not be the case (in my opinion) and if so it is either a set up in customizing or a SAP error.

 

On high level: you have scheduled two "tracking"s (either in the same job or seperate (preferred seperate). SVT should check: Is there a PO relevant for TSCA if yes SVT should be analyze PO  and data will be written to database (if needed) and then you will see the result in CBRC20

 

I propose the following steps to get clear picture:

 

1.) Check for one REAL_SUB having data for TSCA and TSCA 5A

2.) execute the filling

3.) Check content of tables CCRCT_EHS_COMP/CCRCT_EHS_REG first

 

Let us assume n high level example: REAL_SUB contains one SVT relevant data record in a property of type composition e.g. tagged with STANDARD/US). Composition should be on PURE_SUB level; No need to cascade.

 

Two Components should be in place. E.g component A with 40% and B with 60 %

 

CCRCT_EHS_COMP should contain then "identical" data records like:


Regualtion      Material     REAL_SUB     COmponent     Value

TSCA               X               Y                    A                    40

TSCA               X               Y                    B                    60

TSCA 5A          X               Y                    A                    40

TSCA 5A          X               Y                    B                    60


Then check the same for *REG Table. You have prepared data record for two regulations with same "Usage". E.g. TSCA could be 500 T, TSCA A% could be 250 t as limit in the databse.


PLease check this (and my assumptions) and rpvoide feedback about your results


C.B.


PS: if you believe that because of TSCA regulation you need tow different compositions to get tracked you can not ! use this approach as explained. But solution is still possible using SVT


PPS: If I read cross:

the Config is created using separate validity areas and separate reg lists for both, but both have the US assigned.


Question: which validity area you have used per regulation?


pps.

iF i understand your explanation correct:

In CBRC20 you find list, compancode plant, material, spec, tracked spec, value, and trackled value. These values are correct. But the value shown for "threshold"limit etc. is wrong?